What was found
DURING ROUTINE CPCP INSPECTION, FOUND SEVERAL HOLES DRILLED INTO LT FRAME RADIUS AT FS 320, 4, 8 AND 12 ABOVE UPPER CUSP AREA. FABRICATED REPAIR PARTS FOR HOLES IN FRAME AT STA 320 IAW COTNEY DWG NR D93-R19. TREATED AND PRIMED PARTS IAW DC8 SRM 51-1-8, INSTALLED PARTS IAW COTNEY DWG NR D93-R19. CORROSION TASK CARD NUMBER 573L-0551. NON-ROUTINE NR 04899 TASK NR Y1388.