What was found
DURING ROUTINE CPCP INSPECTION, FOUND SEVERAL HOLES DRILLED INTO LT FRAME AT FS 340, 5 ABOVE UPPER CUSP AREA. INSTALLED RIVETS IN MISDRILLED HOLES IN RADIUS IAW DC8 SRM 51-1-21, FABRICATED DOUBLER AND SHIM IAW COTNEY DWG NR D93-R11, TREATED AND PRIMED IAW DC8 SRM 51-1-8 AND INSTALLED DOUBLER AND SHIM IAW DC8 SRM 51-1-20D. CORROSION TASK CARD NUMBER 573L-0551. NON-ROUTINE NR 04900 TASK NR Y1389.