What was found
DURING ROUTINE CPCP INSPECTION, FOUND SEVERAL HOLES DRILLED ON LT FRAME RADIUS AT FS 834, 5 ABOVE UPPER CUSP AREA. PLUGGED MISDRILLED HOLES, FABRICATED DOUBLER AND SHIM IAW COTNEY DWG NR D93-R68. REMOVED AND REPLACED GUSSET IAW COTNEY DWG NR D93-R65, TREATED AND PRIMED IAW DC8 SRM 51-1-8, INSTALLED DOUBLER AND SHIM IAW DC8 SRM 51-1-21 HEAT TREAT IAW 51-1-1. CORROSION TASK CARD NUMBER 573L-0551. NON-ROUTINE NR 04936 TASK NR Y1394.