What was found
DURING ROUTINE CPCP INSPECTION, FOUND SEVERAL HOLES DRILLED INTO LT FRAME AT FS 980, 5 ABOVE UPPER CUSP AREA. PLUGGED HOLES AND SMOOTHED CORNERS IAW COTNEY DWG NR D93-R67. FABRICATED REPAIR ANGLE AND DRILLED HOLES IAW COTNEY DWG NR D93-R67. TREATED AND PRIMED IAW DC8 SRM 51-1-8. INSTALLED REPAIR ANGLE AT STA 980 LT IAW COTNEY DWG NR D93-R67 AND DC8 SRM 51-1-20D. CORROSION TASK CARD NUMBER 573L-0551. NON-ROUTINE NR 04940 TASK NR Y1398.