As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING ROUTINE CPCP INSPECTION, FOUND SEVERAL HOLES DRILLED IN LT FRAME AT FS 1320, 5 ABOVE UPPER CUSP AREA AND AT LT FRAME RADIUS, 22 ABOVE UPPER CUSP AREA. REPAIRED SEVERAL HOLES DRILLED INTO LT FRAME AT FS 1320 5 ABOVE CUSP AND LT FRAME RADIUS 22 ABOVE CUSP PER COTNEY DWG NR D93-R01. CORROSION TASK CARD NUMBER 573L-0551. NON-ROUTINE NR 04951 TASK NR Y1409.