What was found
DURING ROUTINE CPCP INSPECTION, FOUND SEVERAL HOLES DRILLED INTO LT FRAME AT FS 1380, 5 ABOVE UPPER CUSP AREA. FABRICATED, DRILLED, HEAT-TREATED, TREATED AND PRIMED AND INSTALLED FILLER AND SHIM ON LT FRAME AT FS 1380 IAW COTNEY DRAWING D93-R40 AND DC8 SRM 51-1-8 AND 51-1-21. CORROSION TASK CARD NUMBER 573L-0551. NON-ROUTINE NR 04954 TASK NR Y1412.