What was found
DURING ROUTINE CPCP INSPECTION, FOUND SEVERAL HOLES DRILLED INTO LT FRAME AT FS 1440, 5 ABOVE UPPER CUSP AREA. FABRICATED REPAIR PARTS FOR STA 1440 LT SIDE, 5 ABOVE CUSP AREA. DRILLED UP PARTS. TREATED AND PRIMED PARTS, INSTALLED -3 SHIM -2 ANGLE -4 SHIM -1 ANGLE -5 GUSSET IAW COTNEY DRAWING D93-R22 AND DC8 SRM 51-1-20D AND 51-1-8. CORROSION TASK CARD NUMBER 573L-0551. NON-ROUTINE NR 04956 TASK NR Y1414.