What was found
DURING ROUTINE CPCP INSPECTION, FOUND SEVERAL HOLES DRILLED INTO LT FRAME AT FS 1480, 5 ABOVE UPPER CUSP AREA AND ON LT FRAME RADIUS FROM 9 TO 44 ABOVE UPPER CUSP AREA. DEEP GOUGE ON LT FRAME AT FS 1480, 5 ABOVE UPPER CUSP AREA. ROUTED OUT DAMAGED AREA, DID DYE PENETRANT TEST. REMOVED FASTENERS AS NEEDED, FAB REPAIR ANGLE, SHIMS AND FILLERS DRILLED AND DEBURRED. REPAIR PARTS HEAT TREATED A, B AND C ANGLES IAW DC8 SRM 51-1-1 ON LT FRAME AT FS 1480 FROM 5 TO 44 ABOVE UPPER CUSP AREA IAW COTNEY DRAWINGS D93-R41 TREATED, PRIMED, SEALED AND INSTALLED PARTS -1 -2 AND -3 IAW COTNEY DRAWING D93-R41. CORROSION TASK CARD NUMBER 573L-0551. NON-ROUTINE NR 04958 AND 04959 TASK NR Y1416.