What was found
DURING ROUTINE CPCP INSPECTION, FOUND SEVERAL HOLES DRILLED INTO LT FRAME AT FS 1500 5 ABOVE UPPER CUSP AREA. REMOVED DAMAGED AREA OF FRAME OF LT FRAME FS 1500 5 ABOVE UPPER CUSP. FAB REPAIR STRAP AND SHIM, FITTED, DRILLED, AND DEBURRED FRAME, SHIM AND STRAP IAW COTNEY DWG NR D93-R70. TREATED, PRIMED, SEALED AND INSTALLED REPAIR STRAP AND SHIM ON LT FRAME AT FS 1500 5 ABOVE CUSP IAW COTNEY DWG NR D93-R70. CORROSION TASK CARD NUMBER 573L-0551. NON-ROUTINE NR 04961 TASK NR Y1418.