What was found
DURING ROUTINE CPCP INSPECTION, FOUND SEVERAL HOLES DRILLED INTO LT FRAME RADIUS AT FS 1540, 5 ABOVE UPPER CUSP AREA. FABRICATED AND INSTALLED NEW ANGLE FOR FRAME REPAIR AT FS 1540 LT, 5 ABOVE UPPER CUSP AREA PER COTNEY DRAWING D93-R72. FABRICATED, HEAT AND AGED. TREATED AND PRIMED REPAIR PART IAW COTNEY DWG NR D93-R72, DC8 SRM 51-1-1 AND 51-1-8. INSTALLED REPAIR IAW COTNEY DWG NR D93-R72. CORROSION TASK CARD NUMBER 573L-0551. NON-ROUTINE NR 04963 TASK NR Y1420.