What was found
DURING ROUTINE CPCP INSPECTION, FOUND LEVEL 2 CORROSION. CORROSION ON DOUBLER FS 1050 LONG 31LT. CLEANED CORROSION ON SPLICE PLATE IAW DC8 SRM 51-1-8. CORROSION REMOVAL OUT OF LIMITS IAW DC8 SRM 53-2-0 FIG 1F. REMOVED SPLICE PLATE IAW DC8 SRM 51-1-20D AND 51-1-21. FABRICATED REPLACEMENT SPLICE PLATE IAW DOUGLAS DWG 5779936 AND DC8 SRM 53-4-1 FIG 44 SHEET 1 PAGE 161. TREATED AND PRIMED SPLICE PLATE IAW DC8 SRM 51-1-8. INSTALLED SPLICE PLATE IAW DC8 SRM 51-1-20D AND 51-1-21. CORROSION TASK CARD NUMBER 5590-0551. NON-ROUTINE NR 04613 TASK NR X0043.