What was found
DURING ROUTINE CPCP INSPECTION, FOUND LEVEL 2 CORROSION. CORROSION OF FLOOR FRAME STA 240 ABOVE LONGERON 35L A PIT. AFTER REMOVAL OF CORROSION FLOOR FRAME OUT OF LIMITS. FABRICATED REPAIR FILLER AND DOUBLERS IAW DC8 SRM 53-2-0 FIG 2. HEAT TREATED AND AGED PARTS IAW DC8 SRM 51-1-1. LOCATED AND DRILLED REPAIR PARTS. TREATED AND PRIMED IAW DC8 SRM 51-1-8. INSTALLED REPAIR IAW DC8 SRM 53-2-0 FIG 2 ON FS 240 ABOVE LONGERON 35 LT. CORROSION TASK CARD NUMBER 5570-0551. NON-ROUTINE NR 02536 TASK NR X0029.