DURING ROUTINE CPCP INSPECTION, FOUND LEVEL 2 CORROSION, FS 1700 STRINGER 29R CRACKED AT END. STRESS CRACK (CORROSION) .0625 TO END OF STRINGER 29R FROM LAST FASTENER. REPAIRED STRINGER IAW EDR NO D805818 AND AIA/E/2808 DTD APRIL 18, 1998. CORROSION TASK CARD NUMBER 5600-0551. NON-ROUTINE TASK CARD NUMBER 23341.