What was found
DURING ROUTINE B-CHECK INSPECTION, FOUND RT SIDE FS 1200 SKIN ABOVE NLG STRUT DOOR CRACKED. REMOVED DOOR AND ACCESS PANEL AS REQUIRED. REMOVED DAMAGED AREA IAW DC8 SRM 53-02-01. REPAIRED DAMAGED AREA IAW DC8 SRM 53-02-01. INSTALLED ACCESS PANEL AND DOOR IAW DC8 MM 21-54-2. CLASS II REPAIR INSTALLED INITIAL REINSPECTION DUE IN 12000 CYCLES REINSPECT THEREAFTER DUE EVERY 4000 CYCLED. REPAIR MUST BE REPLACED WITHIN 24000 CYCLES IAW DC8 SRM 53-2-1 PARAGRAPH 16. NON-ROUTINE TASK CARD NUMBER 23645.