What was found
DURING ACCOMPLISHMENT OF CPCP TASK 376L-0551, FOUND LEVEL 2 CORROSION AT L HORIZ STAB UPPER AND LWR SFC SKIN PANEL BETWEEN STA XE221 AND XE272. REPLACED PANEL IAW SRM 55-2-0. FOUND DURING D CHECK, ROUTINE CPCP TASK CARD ACCOMPLISHMENT AT SIMON (LIMA PERU). WORK ORDER NUMBER 818-166, NON ROUTINE TASK CARD NUMBER 38153, CPCP TASK CARD NUMBER 376L-0551.