What was found
CORROSION FOUND ON SKIN PANEL AT FS 1107 BETWEEN STRINGERS 29 TO 30. FOUND TO BE OUT OF LIMITS IAW SRM 53-31-00. TREATED PRIMED IAW SRM 51-21-02 AND MM 20-51-09. REPAIRED IAW SRM 51-50-01. FOUND DURING SCHEDULED C-CHECK AND CPCP WORK CARD ACCOMPLISHMENT AT AIA. MAINTENANCE FACILITY IN OSCODA, MI. WORK ORDER NR 106-187, NON ROUTINE CARD NR 35891, AIA CPCP TASK NR 01-00-1009.