What was found
IN C-2 PIT FS 1485 BETWEEN STRINGERS 35 TO 36 FOUND SHEAR TIE CORRODED. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 51-21-01 AND 53-23-00. FABRICATED REPAIR PARTS IAW SRM 53-12-00 FIG 804. TREATED, PRIMED AND INSTALLED REPAIR IAW L1011 SRM 51-21-02. FOUND DURING SCHEDULED C-CHECK AND CPCP WORK CARD ACCOMPLISHMENT AT AIA. MAINTENANCE FACILITY IN OSCODA, MI. WORK ORDER NR 106-187, NON ROUTINE CARD NR 34243, CPCP TASK NR C53-120-04-03.