C-1 DOOR INTERNAL WEB FRAME HAS CORROSION AROUND ANCHOR NUT HOLES IN FOUR AREAS. REMOVED CORROSION IAW SRM 51-21-01. COMPLIED WITH THICKNESS CHECK, FOUND FOUR AREAS OUT OF LIMITS IAW SRM 52-11-00. FABRICATED REPAIR PARTS IAW AIA DRAWING EDR-L106044. TREATED AND PRIMED IAW L1011 SRM 51-10-02 AND MM 20-51-09. INSTALLED REPAIR IAW AIA DRWG EDR-L106044. FOUND DURING SCHEDULED C-CHECK AND CPCP WORK CARD ACCOMPLISHMENT AT AIA. MAINTENANCE FACILITY IN OSCODA, MI. WORK ORDER NR 106-187, NON ROUTINE CARD NR 31502, CPCP TASK NR 08-00-1000.