What was found
LOCATED AT ZONE 250 MID CABIN, BS 2240, FLOORBEAM HAS AREA OF CORROSION FROM LBL62 TO LBL 82. REMOVED CORROSION IAW SRM 51-10-01, FOUND TO BE OUT OF LIMITS IAW SRM 53-10-01. REPAIRED FLOORBEAM IAW SRM 51-40-04 FIG 1, TREATED IAW SRM 53-10-02. FOUND DURING SCHEDULED C-CHECK AND CPCP TASK CARD ACCOMPLISHMENT AT HAECO MAINTENANCE/REPAIR FACILITY, IN HONG KONG (VHKG). C-CHECK WORK CARD NR 7CI2018, NON ROUTINE TASK CARD NR JF55230.