What was found
DURING ACCOMPLISHMENT OF ROUTINE C-CHECK INSPECTION WORK CARD NR 05-57-1006, FOUND LT SIDE NR 7 LEADING EDGE SLAT RIBS NR 4 AND 21 TO BE CRACKED. REMOVED LT SLAT NR 7 IAW MM 27-81-26, REPAIRED CRACKED RIBS IAW SRM 57-51-00, RE-INSTALLED LT NR 7 SLAT IAW MM 27-81-26. OPS CHECK GOOD IAW MM 27-81-00 PG 6. FOUND DURING SCHEDULED C-CHECK INSPECTION AT GAMCO, INC.