What was found
DURING C-CHECK INSPECTION, FOUND LT WING NR 2 SLAT SCREW JACK SHEARED OFF FROM UPPER MOUNT. REMOVED NR 2 SLAT ACTUATOR IAW MM 27-81-00. DURING INSPECTION, FOUND TORQUE TUBE O/B OF NR 2 SLAT ACTUATOR DAMAGED. REMOVED AND REPLACED IAW MM 27-81-18. SLAT ACTUATOR UPPER MOUNT RE-INSTALLED WITH NEW BOLTS IAW MM 27-81-27. RE-INSTALLED NR 2 SLAT ACTUATOR IAW MM 27-81-21. OPS CHECK SATISFACTORY IAW MM 27-81-00. FOUND DURING ACCOMPLISHMENT OF SCHEDULED C-CHECK AT GAMCO, INC. WORK CARD 57686, C-CHECK CARD 05-00-1001, NON-ROUTINE WORK CARD NR 1020.