What was found
DURING ACCOMPLISHMENT OF C-CHECK, FOUND RT ELEVATOR TIP, TOP ON/OFF PLATE CRACKED AND HAVING SHEARED RIVETS. REMOVED CRACKED DOUBLER ON/OFF PLATE AS PER SRM 51-40-01. FABRICATED REPAIR DOUBLER, DEBUR AND PRE-PROTECT AS PER SRM 51-21-02. INSTALLED DOUBLER AS PER SRM 51-40-01. REPAIR CARRIED OUT IAW SRM 51-50-02. FOUND DURING ACCOMPLISHMENT OF SCHEDULED C-CHECK AT GAMCO, INC. WORK CARD 57686, C-CHECK CARD 03-55-1004, NON-ROUTINE WORK CARD NR 5008.