What was found
DURING ACCOMPLISHMENT OF C-CHECK INSPECTION, FOUND CRACK 4 INCHES LONG AT SLAT NR 7 RT I/B UPPER CORNER WITH 4 RIVETS SHEARED. STOP DRILLED CRACK AS PER SRM 51-10-04. FABRICATED REPAIR DOUBLER, BACK DRILLED, TRIMMED AND PRE-PROTECT AS PER SRM 51-21-02. INSTALLED REPAIR DOUBLER INTO POSITION AS PER SRM 51-40-01. REPAIR CARRIED OUT IAW SRM 57-51-00 FIG 807. TOUCH UP PAINT CARRIED OUT IAW MM 20-51-11. FOUND DURING ACCOMPLISHMENT OF SCHEDULED C-CHECK AT GAMCO, INC. WORK CARD 57686, C-CHECK CARD 57-00-100-2, NON-ROUTINE WORK CARD NR 2011.