What was found
DURING ACCOMPLISHMENT OF ROUTINE C CHECK AND SCHEDULED CPCP TASK CARDS, FOUND SUPPORT FITTING CORRODED AREA 1X2 AT ZONE 130, BS 1047, LBL48. FOUND TO BE BEYOND LIMITS IAW SRM 53-10-01. REPAIRED IAW SRM 53-10-01 PG 18. ACCOMPLISHED AT HAECO HONG KONG, CONTRACT NR 2FE, C CHECK TASK CARD NR 7CI1306, NON-ROUTINE WORK CARD NR SU55773.