What was found
DURING ACCOMPLISHMENT OF ROUTINE C CHECK AND SCHEDULED CPCP TASK CARDS, FOUND SKIN DOUBLER CORRODED, AREA APPROX 3X3 AT ZONE 130,BS 980-987, WATER SERVICE BAY. FOUND TO BE BEYOND LIMITS IAW SRM 53-30-01. REPAIRED IAW SRM 51-10-01 PG 18. ACCOMPLISHED AT HAECO HONG KONG, CONTRACT NR 2FE, C CHECK TASK CARD NR 7CI1006, NON-ROUTINE WORK CARD NR SU60971.