What was found
DURING ACCOMPLISHMENT OF ROUTINE C CHECK AND SCHEDULED CPCP TASK CARDS, FOUND SUPPORT ANGLE CORRODED, AREA 1X10 AT ZONE 149, BS 1468, LBL16-RBL16. FOUND TO BE BEYOND LIMITS IAW SRM 53-10-01. REPAIRED IAW SRM 51-10-01 PG 18. ACCOMPLISHED AT HAECO HONG KONG, CONTRACT NR 2FE, CPCP TASK CARD NR C53-190-01-01, NON-ROUTINE WORK CARD NR SU54834.