What was found
DURING ACCOMPLISHMENT OF ROUTINE C CHECK AND SCHEDULED CPCP TASK CARDS, FOUND EMPENNAGE, HORIZ STAB SCREWJACK COMPT DOOR FWD LEFT CORNER FRAME BRACKET OUTER CHORD CORRODED, AREA 1X1 AT ZONE 310, BS 2410, RBL10. FOUND TO BE BEYOND LIMITS IAW SRM 53-30-01. REPAIRED IAW SRM 51-10-01 PG 18 FIG 1. ACCOMPLISHED AT HAECO HONG KONG, CONTRACT NR 2FE, C CHECK TASK CARD NR 7CI1010, NON-ROUTINE WORK CARD NR SU60542.