What was found
DURING ACCOMPLISHMENT OF ROUTINE C CHECK AND SCHEDULED CPCP TASK CARDS, FOUND SEAT TRACK CORRODED, AREA 1X20 AT ZONE 260, BS 1750-1810, RBL75. FOUND TO BE BEYOND LIMITS IAW SRM 53-10-01. REPAIRED IAW SRM 53-10-05 FIG 14. ACCOMPLISHED AT HAECO HONG KONG, CONTRACT NR 2FE, CPCP TASK CARD NR C53-210-01-04, NON-ROUTINE WORK CARD NR SU68750.