What was found
DURING ROUTINE C CHECK AND CPCP, FOUND CORROSION AROUND FASTNERS ON STRINGER 35, STA 1783, C-3 CARGO PIT. REMOVED CORROSION AND FASTNERS IAW SRM 51-21-01. FOUND TO BE OUT OF LIMITS IAW SRM 53-13-00. FABRICATED REPAIR IAW SRM 53-13-00. INSTALLED REPAIR IAW SRM 53-13-00. WORK PERFORMED AT AIA MAINTENANCE FACILITY OSCODA. WORK ORDER NUMBER 106-211, SOURCE DOCUMENT CPCP CARD C53-120-04-03, NON ROUTINE TASK CARD NUMBER 34282.