What was found
DURING ROUTINE ACCOMPLISHMENT OF SCHEDULED C CHECK AND CPCP TASK CARDS, FOUND STRINGER CORRODED AT ZONE 120, STA 649 TO STA 749. DETERMINED TO BE OUT OF LIMITS IAW SRM 53-31-00 FIG 801. REPAIR CARRIED OUT IAW SRM 53-31-00 FIG 827. FOUND AT GAMCO MAINTENANCE FACILITY (ABBU), C CHECK CARD 01-53-1016, CPCP CARD C53-120-04-01, GAMCO NON ROUTINE WORK CARD NR 4078.