What was found
DURING ROUTINE ACCOMPLISHMENT OF SCHEDULED C CHECK AND CPCP TASK CARDS, FOUND LONGERON CORRODED AT ZONE 110, STA 270. DETERMINED TO BE OUT OF LIMITS IAW SRM 51-10-01. REPAIR CARRIED OUT IAW SRM 51-50-02 AND 51-40-01/02. FOUND AT GAMCO MAINTENANCE FACILITY (ABBU), C CHECK CARD 01-00-1008, CPCP CARD C53-110-01-00, NON ROUTINE WORK CARD NR 5072.