What was found
DURING CLIMB, LEVEL 3 "ENG. 3 FIRE" ALERT WAS ANNUNCIATED, PERFORMED APPROPRIATE CHECK LIST AND RETURNED TO DEPARTURE. R & R HIGH TEMP FIRE DETECTOR HARNESS UPPER DECTECTOR IAW AMM 71-50-04, PERFORMED BITE TEST, CHECKED OK IAW MM 26-11-02-700-801. ACFT RETURNED TO SERVICE.