Service difficulty report · Resistor · Doug DC1030

Difficulty date
October 10, 2006
Submitted
October 24, 2006
Operation
Air carrier
Aircraft
N810AX
Make and model
Doug DC1030
Aircraft serial
48265
Aircraft time
83,902 hours, 13,095 cycles
Engine
Ge CF650C2B
Part
Resistor
Part number
R4139
Condition
Failed
Location
Control Panel
Stage of operation
NR
How discovered
V
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING PAX LOADING SMOKE AND ELECTRICAL FUMES NOTED BY CREW, BY L-4 DOOR PA PNL. DE-PLANED ACFT, FIRE DEPT NOTIFIED. INSPECTED L-4 DOOR FLIGHT ATTENDANT PA PANEL WIRING IAW MM 20-30. FOUND WITH FIRE DEPARTMENT THAT THE L-4 DOOR RESISTOR R4-139 HAD OVERHEATED AND POPPED THE L-4 DOOR CONTROL CIRCUIT BREAKER. FOUND THAT NO WIRES WERE DAMAGED. WITH L-4 DOOR CONTROL C/B PULLED THERE IS NO POWER TO RESISTOR R4-139. DEFERRED L-4 DOOR ELECTRICAL OPERATION IAW MEL 52-1 CAT-C. L-4 DOOR ELECTRICALLY INOP DUE TO OVERHEATED RESISTOR R4-139 ON FLIGHT ATTENDANT PANEL (L-4 DOOR)