What was found
BS 1741-1761, STR 38L-39L, INTERCOSTAL IS BROKEN. BROKEN EDGE WAS TRIMMED OUT, INTERCOSTAL WAS REINFORCED WITH AN ANGLE. FABRICATED AND INSTALLED IAW SRM VOL 1 53-00-01, FIG 8. INSTALLED FASTENERS IAW SRM VOL 2, 51-35-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 1741-1761, STR 38L-39L, INTERCOSTAL IS BROKEN. BROKEN EDGE WAS TRIMMED OUT, INTERCOSTAL WAS REINFORCED WITH AN ANGLE. FABRICATED AND INSTALLED IAW SRM VOL 1 53-00-01, FIG 8. INSTALLED FASTENERS IAW SRM VOL 2, 51-35-01.