What was found
STA 878, B/T LBL28 AND LBL60 DEEP CORROSION ON FLOORBEAM. DAMAGED FLOORBEAM REMOVED, NEW FABRICATED IAW SRM VOL 3, 53-13-01 FIG 24 AND GMM 4.45. INSTALLED FASTENERS IAW SRM VOL 2, 51-31-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STA 878, B/T LBL28 AND LBL60 DEEP CORROSION ON FLOORBEAM. DAMAGED FLOORBEAM REMOVED, NEW FABRICATED IAW SRM VOL 3, 53-13-01 FIG 24 AND GMM 4.45. INSTALLED FASTENERS IAW SRM VOL 2, 51-31-01.