What was found
STA 1964, RBL 62 CORROSION ON FLOOR SUPPORT. CORRODED FLOOR SUPPORT REMOVED NEW FABRICATED PN: OAI-53-0017 IAW SRM VOL.3 53-16-01 FIG 8 AND GMM 4.45 AND INSTALLED WITH FASTENERS IAW SRM VOL 2 51-31-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STA 1964, RBL 62 CORROSION ON FLOOR SUPPORT. CORRODED FLOOR SUPPORT REMOVED NEW FABRICATED PN: OAI-53-0017 IAW SRM VOL.3 53-16-01 FIG 8 AND GMM 4.45 AND INSTALLED WITH FASTENERS IAW SRM VOL 2 51-31-01.