What was found
B/T STA 457 AND STA 475, LBL 58, CORROSION ON TRACK. (HOLE AREA) DAMAGED AREA TRIMMED-OUT. REINFORCED AREA WITH DOUBLERS AND FILLERS IAW SRM VOL 1, 53-00-01 FIG, 2 INSTALLED FASTENERS IAW SRM VOL 2, 51-31-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
B/T STA 457 AND STA 475, LBL 58, CORROSION ON TRACK. (HOLE AREA) DAMAGED AREA TRIMMED-OUT. REINFORCED AREA WITH DOUBLERS AND FILLERS IAW SRM VOL 1, 53-00-01 FIG, 2 INSTALLED FASTENERS IAW SRM VOL 2, 51-31-01.