As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBEAM AT FS 1518 AND BL -0- IS CORRODED AT LOWER END. REPAIRED LOWER FLANGE OF FLOORBEAM, PN 146T5143-1 IAW SRM 51-70-12, REF RFTS T-46825. REMOVED NUTPLATES ON FLOORBEAM AT STA 1518 AT LOCATION 12L AND 24L. REMOVED CORROSION. REMOVED CORROSION IAW SRM 53-00-51/101, DETAIL 1.