What was found
FOUND DURING HEAVY CHECK. LEVEL 2 CORROSION: CABIN FLOOR SUPPORT STRUCTURES T-CHANNEL INTERCOSTALS ARE CORRODED BETWEEN STRINGERS 16 AND 17L AND STRINGERS 16 AND 17R, BETWEEN FLOOR BEAMS 36 TO 38 LT AND RT. REMOVED AND REPLACED FLOOR SUPPORT STRUCTURES T-CHANNELS. PN LT S5367800920002, RT S536780920102. WO 72242, NR 200089, 91. (K)