What was found
FOUND DURING HEAVY CHECK AT COE. MAJOR REPAIR: LEVEL 2 CORROSION: SRAS: FOUND CORROSION ON EXTERNAL SURFACE OF FUSELAGE SKIN UNDER THE CARGO DOOR THRESHOLD PROTECTION PLATE. PROTECTION PLATE INSTALLED BY M7 AEROSPACE STC ST01189WI. BLENDED-OUT AREAS OF CORROSION ON EXTERNAL FUSELAGE SKIN PER SRAS DO/TS-2668...4699, DO/TS-2668-08-10359, JUSTIFICATION DOCUMENTS REF: NOTE DO/TS-2717/08. SKIN THICKNESS LEFT AS-IS AFTER BLENDING. (S)