What was found
HEAVY CK COE / MAJOR REPAIR: FLOORBEAM 23A HAS TOOLING MARKS ON TOP OF FLANGE AT BL5R. MEASUREMENT AT TOOL MARK ON FLOORBEAM 23A TOP FLANGE .035 OUT OF LIMITS. FABRICATED AND INSTALLED FLOORBEAM 23A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HEAVY CK COE / MAJOR REPAIR: FLOORBEAM 23A HAS TOOLING MARKS ON TOP OF FLANGE AT BL5R. MEASUREMENT AT TOOL MARK ON FLOORBEAM 23A TOP FLANGE .035 OUT OF LIMITS. FABRICATED AND INSTALLED FLOORBEAM 23A.