What was found
WO 101935 NR 100043 HEAVY CK COE / MAJOR REPAIR / LEVEL 2 CORROSION: FLOORBEAM 13 HAS AREAS OF BARE METAL & CORROSION BETWEEN STRINGERS 14L & 14R. (DEPTH .012"). REPAIR PER STRUCTURAL REPAIR INSTRUCTIONS & SRAS FROM ATR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WO 101935 NR 100043 HEAVY CK COE / MAJOR REPAIR / LEVEL 2 CORROSION: FLOORBEAM 13 HAS AREAS OF BARE METAL & CORROSION BETWEEN STRINGERS 14L & 14R. (DEPTH .012"). REPAIR PER STRUCTURAL REPAIR INSTRUCTIONS & SRAS FROM ATR.