What was found
WO 101935 NR 600012 HEAVY CK COE / MAJOR REPAIR / LEVEL 2 CORROSION: WING TANK LOWER SURFACE HAS EXFOLIATON I NJET PUME CUTOUT (LENGTH 1.5", WIDTH 1.7", DEPTH .030"). REMOVED CORROSION AND REPAIRED PER ATR42 STRUCTURAL REPAIR INSTRUCTIONS AND SRAS, MAJOR REPAIR.