As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
HEAVY CHECK COE / MAJOR REPAIR / DAMAGE: DENT OUT OF LIMITS WITH CREASE 4.4 INCHES FORWARD OF FRAME 45 AT LEFT STRINGER 9. STRINGER SPLICE FROM 5.5 INCHES AFT OF FRAME 44 TO 12.5 INCHES FORWARD OF FRAME 46. COMPLETE SPLICE MEASURES 25.5 INCHES. REFERENCE: SRM 53-81-23.