Service difficulty report · Wire · Aerosp ATR72212

Difficulty date
December 3, 2014
Submitted
December 4, 2014
Operation
Air carrier
Aircraft
N803FX
Make and model
Aerosp ATR72212
Aircraft serial
362
Aircraft time
35,078 hours, 38,951 cycles
Part
Wire
Condition
Chafed
Location
Nr 1 Generator
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIR TURN BACK. ON DEPARTURE DURING CLIMB, THE NR 1 ACW GEN FAULTED. THE QRH WAS CONSULTED & THE CREW ELECTED TO RETURN. NO EMER WAS DECLARED. THE ACFT LANDED WITHOUT INCIDENT. DUE TO ICING CONDITIONS ENROUTE THE ACW GEN WAS NOT DEFERRABLE. AFTER EXTENSIVE TROUBLESHOOTING, MX FOUND A CHAFED WIRE IN THE NR 1 ACW GEN HARNESS. THE WIRE WAS REPAIRED, OPERATIONS CHECKED GOOD & ACFT WAS RETURNED TO SERVICE.