What was found
DURING COMPLIANCE OF TASK NR 002-53-160-610, 2 CRACKS WERE FOUND IN THE PRESSURE FLOOR SKIN NEAR FS 461.0, BETWEEN LBL 9.0 AND RBL 9.0. THE CRACKS RANGE FROM 2.875 INCHES TO 3.125 INCHES IN LENGTH. THE PRESSURE FLOOR SKIN WAS REPAIRED IAW BOMBARDIER REO #610-53-41-102, REV B, DATED 6-8-2003, AND REO#601R-53-41-162, DATED 6-9-2003. OK FOR RETURN TO SERVICE.