What was found
AFT RT FUSE AT FS1057 STR 14R-15R HAS 2.6L X 1.6W X .040D DENT. TRIMMED OUT DAMAGED AREA, LPI OR EDDY CURRENT TO ENSURE NO CRACKS EXIST. FABRICATE AND INSTALL DOUBLER (2024-T3 .063) IAW BRAS EO 601R-53-6952.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT RT FUSE AT FS1057 STR 14R-15R HAS 2.6L X 1.6W X .040D DENT. TRIMMED OUT DAMAGED AREA, LPI OR EDDY CURRENT TO ENSURE NO CRACKS EXIST. FABRICATE AND INSTALL DOUBLER (2024-T3 .063) IAW BRAS EO 601R-53-6952.