Service difficulty report · Circuit Breaker · Cndair CL6002B19

Difficulty date
August 14, 2006
Submitted
August 17, 2006
Operation
Air carrier
Aircraft
N949CA
Make and model
Cndair CL6002B19
Aircraft serial
7080
Aircraft time
27,763 hours, 24,624 cycles
Part
Circuit Breaker
Condition
Malfunctioned
Location
Hyd Pump
Stage of operation
LD
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLIGHT 5470 - DURING FLAP SELECTION FROM 8 DEGREES, RECEIVED 3B HYD PUMP CAUTION MESSAGE. CREW DECLARED AN EMERGENCY, LANDED WITHOUT INCIDENT. FOUND 3B CIRCUIT BREAKER POPPED. RESET CIRCUIT BREAKER, PERFORMED OPS CHECK PER AMM, NO FURTHER DEFECTS NOTED.