What was found
FLOOR STRUCTURE ON RT SIDE FS 280.0 CRACKED. INSTALLED SUPPORT ANGLE ON RT SIDE FUSELAGE IAW CRJ SRM 51-42-06.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR STRUCTURE ON RT SIDE FS 280.0 CRACKED. INSTALLED SUPPORT ANGLE ON RT SIDE FUSELAGE IAW CRJ SRM 51-42-06.