What was found
DURING HMV NR 6 INSPECTION, VISUAL INSPECTION FOUND FS 202.75 PRESSURE WEB CRACKED AT PARKING BRAKE CABLE CUTOUT. ENLARGED CUTOUT TO REMOVE DAMAGE AND INSTALLED A DOUBLER PER CRJ REO 601R-53-11-563.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HMV NR 6 INSPECTION, VISUAL INSPECTION FOUND FS 202.75 PRESSURE WEB CRACKED AT PARKING BRAKE CABLE CUTOUT. ENLARGED CUTOUT TO REMOVE DAMAGE AND INSTALLED A DOUBLER PER CRJ REO 601R-53-11-563.